STEP4:BROILERBURNER
Loosen the screw and pull out the burner from
the support being careful not to damage the
ignitionplugandthethermocouple.
Using a 7 mm [name of the tool] unscrew the
nozzle. Replace the nozzle using the conversion
set supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching
nozzlestoburners.
STEP5:VISUALCHECKS
Beforereinstallingthebottompanel,the
followingvisualcheckmustbeperformedto
ensurethattheconversionhasbeencarriedout
properlyandwithoutdamagetoother
componentsoftherange.
A) CONNECTIONOFTHERMOCOUPLESTO
THERMOSTAT
Thethermocouplesforbothbroilerand
main
ovenburnerareconnectedtothesamemagnet.
Tightgentlythetwoconnectionsalternating
actiononthetwonuts.Donotfullytightenone
thermocouplebeforehavingstartedtotighten
thesecondone.
B) OVENIGNITERANDTHERMOCOUPLE
POSITION
Theappropriategapbetweenthetipofthespark
plugorthermocoupleandtheburnershallbe
approximately1/8’’.